e20-520 Free download
Free Download PassQuick e20-520 Practice Exams
Preparing for the e20-520 exam? Searching e20-520 Braindumps, e20-520 Test Questions, e20-520 Practice Exam, e20-520 Dumps? PassQuick e20-520 is written to coincide with the real test by the experienced IT experts and specialists. With the complete collection of PassQuick Questions and Answers, PassQuick e20-520 is high enough to help the candidates to easy pass this exam easily without any other study materials and no need to attend the expensive training class.
Free e20-520 PDF Download
Exam : EMC E20-520
Title : calriion solutions specialist exam
1. Which feature does the PowerPath GUI provide to users?
A. Change the failover policy of a LUN
B. Change the CLARiiON SP from active to standby
C. Provide the CLARiiON with active-active failover policy
D. PowerPath is required for a host to connect to a storage group
Answer: A
2. What is a feature of Access Logix?
A. LUN Masking
B. Controls access to data through file locking
C. Masks host WWNs via Access Control lists
D. Restricts one host at a time to accessing one LUN at a time
Answer: A
3. Which event occurs when starting a new SnapView Snapshot session against a source LUN?
A. The creation of a session name
B. The creation of a SnapView Snapshot
C. The association of a SnapView Snapshot with the session
D. The copying of production data blocks to the Reserved LUN pool
Answer: A
4. The CFM Corporation believes its data is going through the wrong switch in the fabric. They put a protocol analyzer online to capture the output. Where should they look to see if the data is being routed incorrectly?
A. The fourth byte of the destination WWPN
B. The eighth byte of the destination WWPN
C. The first byte of the destination Fibre Channel address
D. The second byte of the destination Fibre Channel address
Answer: C
5. THB Corporation has a database consisting of one log LUN and four data LUNs. The company plans to mirror the database to two remote locations with MirrorView/S. How should it plan to maintain the consistency of the database?
A. Create a MirrorView/S consistency group, and ensure that all five mirrors are members of the consistency group
B. Consistency cannot be maintained with MirrorView/S. They should consider MirrorView/A with consistency groups
C. Consistency cannot be maintained because MirrorView/S does not support consistency groups with two secondary images
D. Consistency cannot be maintained because MirrorView/S does not support consistency groups where log LUNs are members
Answer: C
6. What is an attribute of a Clone Private LUN?
A. Contains Fracture Logs
B. Contains Write Intent Logs
C. Must be the same RAID type as the source LUN
D. Shared by both storage processors simultaneously
Answer: A
7. Which feature does the PowerPath CLI provide to users?
A. Set the failover policy for a LUN
B. Provide the CLARiiON with active-active failover policy
C. PowerPath is required for a host to connect to a storage group
D. Mask any of the LUNs on the storage array connected to the host
Answer: A
8. In an Emulex HBA Solaris host Installation, which file is edited to force the host to perform a Fabric login to a switch?
A. sd.conf
B. lpfc.conf
C. lputil.conf
D. /etc/system
Answer: B
9. After completing the CLARiiON SAN attach procedure, the Windows host is not logging into the Storage Processor. What is one condition that can cause the problem?
A. Improper zoning
B. Incorrect sd.conf
C. Did not install Agent
D. Did not install PowerPath
Answer: A
10. The VisualSRM agent installation can be performed locally on each host. What other method can be used for installation?
A. pkgadd utility
B. Pull installation
C. Push installation
D. At system reboot
Answer: C
11. What is a characteristic of Event Monitor?
A. Integrated with Navisphere Manager
B. Loaded as a separately purchased NDU
C. Monitors for hardware-related events only
D. Monitors only for Navisphere defined events
Answer: A
12. Which statement best describes the source LUN when using LUN migration?
A. Can be a private LUN
B. Cannot be a metaLUN
C. Can be in the process of binding
D. Cannot be a component of a metaLUN
Answer: D
13. Which option is selectable in the Create RAID Group dialogue box?
A. RAID Type
B. RAID Group ID
C. Enable Write Cache
D. Manual Destroy after LUN is unbound
Answer: B
14. How does a SAN Copy session failover upon SP failure?
A. Automatically, via PowerPath
B. Manually, via user intervention
C. Conditionally, via host intervention
D. Automatically, via storage system redundancy
Answer: B
15. Which Navisphere Event Monitor model uses an SP agent to monitor only the storage system on which the SP agent resides?
A. Individual
B. Enterprise
C. Distributed
D. Centralized
Answer: C
16. Which function is disabled when PowerPath is installed without a license key?
A. Failover
B. Multipathing
C. LUNZ functionality
D. Access to peer SP paths
Answer: B
17. What is one way a Snapshot provides a "point-in-time" view of a source LUN?
A. By writing the new data to the Reserved LUN pool each time it changes
B. By writing the new data to the Reserved LUN pool the first time it changes
C. By copying the original data to the Reserved LUN pool the first time it changes
D. By limiting the number of Snapshots to eight that can be assigned to a LUN at the same time
Answer: C
18. What is a valid Navisphere CLI command?
A. navicli getlun -h 192.168.2.125
B. navicli -d 192.168.2.125 getlun -rg
C. navicli -h 192.168.2.125 getlun -rg
D. java.jar navicli -address 192.168.2.16 metalun -list
Answer: C
19. Which feature best describes the PSM LUN on the CX series?
A. Each SP accesses its own copy
B. Default size is 2GB on a CX array
C. Not viewable in Navisphere Manager
D. Created after array initialization by the user
Answer: C
20. Which combination is supported for a SAN Copy transfer?
A. SAN Copy/E licensed on a CX200 connected to a CX500 with SAN Copy licensed
B. SAN Copy/E licensed on a CX300 connected to a CX500 with SAN Copy licensed
C. SAN Copy/E licensed on a CX500 connected to a CX500 with SAN Copy licensed
D. SAN Copy/E licensed on a CX500 connected to a CX700 with SAN Copy licensed
Answer: B
Recommended Training about EMC e20-520 testing Fromat
The following courses are the recommended training for e20-520 PDF Fromat.
e20-520 Q & A with Explanations
e20-520 Audio video download
e20-520 Study Guide materials
e20-520 Preparation Labs
e20-520 paper books
e20-520 rapidshare 4shared sadikhov links
e20-520 torrent notes
e20-520 self testengin
e20-520 sample print pdf version
Why do you Choose PassQuick e20-520
Quality and Value for the e20-520 Exams
PassQuick Practice Exams for EMC Certification e20-520 are written to the highest standards of technical accuracy, using only certified subject matter experts and published authors for development.
100% Guarantee to Pass e20-520 Exam
If you prepare for e20-520 exam using our PassQuick testing engine, we guarantee your success in the first attempt. If you do not pass the e20-520 exam on your first attempt we will give you a FULL REFUND of your purchasing fee AND send you another same value product for free.
No related posts.
Related posts brought to you by Yet Another Related Posts Plugin.